Viscosity

CANNON MANNING / FENSKE VISCOMETER

HT-715

Reference Standards: IS 1206 (Part II & III)

This viscometer system is used for determining absolute and kinematic viscosity of bitumen and petroleum products using capillary flow under controlled temperature and vacuum conditions.

The method involves measuring the time taken for a liquid to flow through a calibrated glass capillary tube. The viscosity is calculated using flow time and calibration constants.

The system is widely used in advanced laboratories for high-precision viscosity measurement.

Key Features

  • Dual functionality (absolute & kinematic viscosity)
  • Vacuum-assisted testing
  • Multi-sample bath (up to 4 tests)
  • Digital temperature control
  • High accuracy and repeatability

Technical Specifications

  • Temperature range: -20°C to 300°C
  • Vacuum: Up to 650 mm Hg
  • Bath: Double layer with stirrer
  • Power: 230V

Ordering Information

HT-715            Cannon Manning cum Cannon Fenske Viscometer bath with Digital            Vacuum Pump

 Note: Viscometer tubes can be ordered separately in various sizes at additional cost.

Solvent Recovery Unit

On-flammable solvent liquids used for the binder extraction test can be successfully recovered using the solvent recovery unit.
The recovery unit consists of two stainless steel chambers, one for the dirty used solvent and the other for the cleaned recovered solvent. Solvent in the left-hand side chamber is distilled by an electrical heater and then passes through a water cooling system and drops into the second chamber ready for re-use. A temperature switch automatically stops the heating elements when the recovery process is completed. The unit is supplied complete with 10 m plastic tubing, tube clamps, sieve insert 0.6 mm opening and one lid.
The solvent recovery unit is supplied complete with:

  •   Plastic tubing, 10 m
  •   Sieve insert, 0.6 mm
  •   Tube clamps
  •   Lid
bit18

Say Bolt Viscometer

ASTM D88, D244, AASHTO T72
Say bolt Viscometer, Electrically Heated, ASTM D88, D244, AASHTO T72 for the empirical measurement of Say bolt Viscosity of petroleum products at specified temperatures between 70OF and 210OF. This is also used for determining the Saybolt Furol Viscosity of bituminous materials at temperatures of 250, 275, 300, 350, 400 and 450OF. It comprises one each of Cylindrical Oil Cup, Universal Tip, Furol Tip, Bath Fitted with immersion Heater mounted on a stand. Dimmer stat for temperature control, Stirrer with shield. Complete with insulated handle and thermometer support receiving flask, withdrawal tube, filter funnel, thermometer support for cup and circular spirit level. Suitable for operation on 230 V 50 Hz, Single Phase, A.C.

Optional Extras

  •   Brass Oil Tube
  •   Receiving Flask, 60ml
  •   Universal and Furol Tip (Set of 2)
  •   Filter Funnel
  •   Thermometer Support
  •   Heating Coil
  •   ASTM Thermometer Type 18 F Range: 66oF to 80oF
  •   ASTM Thermometer Type 19 F Range: 94oF to 80oF
  •   ASTM Thermometer Type 19 F Range: 120oF to 148oF
  •   ASTM Thermometer Type 20 F Range: 134oF to 148oF
  •   ASTM Thermometer Type 21 F Range: 174oF to 188oF
  •   ASTM Thermometer Type 22 F Range: 204oF to 218oF
  •   ASTM Thermometer Type 77 F Range: 245oF to 265oF
  •   ASTM Thermometer Type 77 F Range: 295oF to 315oF
  •   ASTM Thermometer Type 78 F Range: 345oF to 365oF
  •   ASTM Thermometer Type 80 F Range: 395oF to 415oF
  •   ASTM Thermometer Type 81 F Range: 445oF to 465oF
bit19

Saybolt Two-Tube Digital Viscometer

ASTM D88, AASHTO T72
The viscometer can be used for temperatures between 21 to 99oC (70 to 210oF) the viscometer includes water- oil bath, stirrer, cooling coil, electric heater with digital thermo regulator, furol orifice, universal orifice, thermometer support and 2 x 60 ml glass Saybolt Viscosity Flask.
Viscosity thermometer set consists of 6 thermometers with the temperature ranges; 19 to 27oC, 34 to 42oC, 49 to 57oC, 57 to 65oC, 79 to 87oC (250 mm length) and 95 to 103oC where each thermometer with 0.1oC subdivisions. Filter funnel, withdrawal tube and thermometer set should be ordered separately.

bit20

STANDARD TAR VISCOMETER (4 mm & 10 mm)

HT-713 & HT-714

Reference Standards: IS 1206 (Part I), IP 72, BS 2000

The Standard Tar Viscometer is used to determine the viscosity of bitumen, tar, and cutback bitumen by measuring the time taken for a fixed volume of sample to flow through a standard orifice.

The test is based on gravity flow principle, where viscosity is proportional to the time required for efflux through the orifice. The apparatus includes a heated bath, test cup with valve, and temperature measurement system.

This equipment is essential for evaluating flow characteristics and application behavior of bituminous binders in road construction.

Key Features

  • Chrome plated copper bath
  • Electric heating with dimmerstat
  • Precision orifice cups (4 mm or 10 mm)
  • Stirrer with insulated handle
  • Stable structure with leveling

Technical Specifications

  • Temperature range: Ambient to 200°C
  • Cup sizes: 4 mm or 10 mm
  • Heating: Electric
  • Power: 230V

Ordering Information

HT-713            Standard Tar Viscometer, 10 mm cup

HT-714            Standard Tar Viscometer, 4 mm cup